Condition establishment study of the direct peptide reactivity
assay in Korea

Kyo-Hyun Park1, Goon-Cheol Song2, Hwan-Yong Choo3, Yong Heo4, Bae-Hwan Kim1†
1Department of Public Health, Keimyung University
2Croen Institute
3Toxicity Evaluation Team of Korea Testing & Research Institute
4Deptartment of Occupational Health, Catholic University of Daegu

Abstract

The purpose of this study is to set the method condition of the DPRA in Korea throughout reproducibility study. We conducted intra-lab (triplicate) and inter-lab (three labs of CRI, KTR and CU) validation using 20 chemicals (10 chemicals for the proficiency test listed in the OECD test guideline 442C and an additional 10 more chemicals from reference papers). The data from all three labs met the acceptance criteria. Upon intra-lab validation, two positive chemicals out of 20 total chemicals showed false negative, and one negative chemical showed false positive. In inter-lab validation of three labs, the sensitivity data were 83, 83 and 88% each, and the specificity data was 100, 100 and 88% each. So the accuracy of the three labs was equal to 90%. During these studies, we also checked and improved various limitations that arose. Taken together, the results indicated that the DPRA proposed by OECD test guideline 442C is expected to become a well-established method under Korean GLP applied system.